Setting Up Your Flex 5600 SXT Digital Water Softener Control Valve
In this article, we will guide you through the process of setting up your Flex 5600 SXT digital water softener control valve. This control valve allows you to program and customize various settings for your water softener system. By following these step-by-step instructions, you will be able to accurately set up your control valve for optimal performance and efficiency. Let's get started!
Introduction
Water softeners are essential for removing minerals that cause hard water, ensuring clean and soft water for everyday use. The Flex 5600 SXT digital water softener control valve offers advanced features and settings to customize your water softening experience. In this article, we will walk you through the process of programming your control valve from setting the time of day to adjusting the hardness and regeneration settings.
Setting the Time of Day
To access the master programming mode, you need to set the time of day to a specific time, such as 12:01 PM. Start by pressing and holding the up or down arrow button to adjust the time. Aim for 12:01 PM or whenever you want to set as your reference point. Make sure the time shows "PM" and use the cycle button to lock it in.
Entering the Master Programming Mode
To enter the master programming mode, press and hold both the up and down arrow buttons simultaneously. After a couple of seconds, you should see "DFGAL" appear on the screen. This indicates that you have successfully entered the master programming mode.
Advancing Through Each Setting
In the master programming mode, you can now advance through each setting and ensure they are set correctly. Use the cycle button to move to the next setting after confirming the current setting. Let's explore the essential settings you need to configure for your water softener control valve.
Setting the Programmed Time of Day
The first setting to check is the programmed time of day. Make sure it is correctly set after entering the programming mode. Use the cycle button to advance to the next setting if the time is already accurate.
Setting the Capacity
The capacity setting depends on the size of your water softener system. Refer to the provided table to determine the appropriate setting. Adjust the value accordingly using the cycle button.
Setting the Hardness
The hardness setting should reflect the level of hardness in your water, measured in grains per gallon. Use a water hardness test kit to determine the value accurately. If your water contains iron, add five to the hardness value for each part of iron present.
Setting the Regeneration Type
The "RS" setting should display on the top left and "RC" in lowercase in the center. If this is the case, move on to the next setting using the cycle button.
Setting the Regeneration Time
The regeneration time (RT) is the time of day when the system will regenerate. This should be set to a time when water usage is minimal or when no one is using water. The default setting is 2 o'clock in the morning, which is recommended in most cases.
Setting the Backwash and Brine Refill Times
The "BW" setting determines the backwash time. Refer to the provided table to set the appropriate value based on your system's size. The "BD" setting represents the brine refill time and should be left unchanged.
Setting the Brine Flow Rate
The "RR" setting determines the brine flow rate. The default value of 10 should be suitable for most scenarios. Use the cycle button to move to the next setting.
Setting the Flow Meter Type
The last setting to configure is the flow meter type. The Flex 5600 SXT control valve comes with either a paddle wheel meter or a turbine meter. Ensure that the corresponding value, "P0.7" for a paddle wheel meter or "T0.7" for a turbine meter, is correctly set.
Conclusion
With these step-by-step instructions, you can easily program your Flex 5600 SXT digital water softener control valve. By adjusting the essential settings, such as the time of day, capacity, hardness, and regeneration times, you can ensure optimal performance and soft water throughout your home. If you have any further questions or need assistance, do not hesitate to contact us. Enjoy the benefits of clean and soft water with your newly programmed control valve!
Highlights:
- Program your Flex 5600 SXT digital water softener control valve with ease
- Adjust essential settings such as time of day, capacity, and hardness
- Customize regeneration times for optimal efficiency
- Enjoy the benefits of clean and soft water throughout your home
FAQ:
Q: How do I access the master programming mode on my Flex 5600 SXT control valve?
A: To access the master programming mode, set the time of day to 12:01 PM and then press and hold both the up and down arrow buttons simultaneously.
Q: What should I set the hardness value to if my water contains iron?
A: For every part of iron present in your water, add five to the hardness value. For example, if your water is 20 grains hard with one part of iron, set the hardness value to 25.
Q: Can I change the regeneration time to a different time of day?
A: Yes, you can adjust the regeneration time to any time you prefer. However, it is recommended to choose a time when water usage is minimal or when no one is using water, such as 2 o'clock in the morning.
Q: How do I determine the appropriate capacity setting for my water softener system?
A: Refer to the provided table that outlines the capacity setting based on your system's size. Set the capacity value accordingly using the cycle button.