Mastering CT Image Quality: Understanding and Overcoming Artifacts
Table of Contents
- Introduction
- Types of Artifacts
- Physics-Based Artifacts
- Beam Hardening Artifacts
- Partial Volume Artifacts
- Under Sampling Artifacts
- Patient-Based Artifacts
- Scanner-Based Artifacts
- Helical and Multi-Section Technique Artifacts
- Beam Hardening Artifacts
- Cupping Artifact
- Streaks and Dark Bands Artifact
- Minimizing Beam Hardening Artifacts
- Partial Volume Artifacts
- Causes and Effects
- Minimizing Partial Volume Artifacts
- Under Sampling Artifacts
- View Aliasing
- Ray Aliasing
- Minimizing Under Sampling Artifacts
- Patient-Based Artifacts
- Movement Artifacts
- Metallic Artifacts
- Scanner-Based Artifacts
- Imperfection Artifacts
- Helical and Multi-Section Technique Artifacts
- Image Reconstruction Artifacts
- Conclusion
👉 Physics-Based Artifacts
Artifacts in CT imaging can significantly affect the quality and diagnostic value of the images. These artifacts can arise from errors in perception or representation of information introduced by techniques or modalities used in CT imaging. Among these artifacts, physics-based artifacts can have a substantial impact on image degradation and diagnostic accuracy. In this article, we will delve into the different types of physics-based artifacts, their causes, and how they can be corrected or minimized.
Beam Hardening Artifacts
🔍 Cupping Artifact
One of the most common physics-based artifacts is the cupping artifact. This artifact occurs when X-rays passing through a uniform cylinder undergo different levels of beam hardening depending on their path. As a result, the projection of the cylinder appears darker in the center and brighter at the edges, resembling a cup shape. This artifact can distort the CT numbers and affect the accuracy of the image.
Pros:
- Cupping artifacts can be corrected using calibration corrections and iterative beam hardening correction software.
Cons:
- Cupping artifacts can mimic clinical lesions and lead to misinterpretation.
🔍 Streaks and Dark Bands Artifact
Another type of beam hardening artifact is the streaks and dark bands artifact. This artifact occurs when the X-ray beam passes through areas of high density, such as contrast-enhanced blood vessels or metallic objects. The differences in attenuation between objects can cause streaks and dark bands to appear in the image, obscuring details and reducing the overall image quality.
Pros:
- Streaks and dark bands artifacts can be minimized by applying calibration corrections and iterative beam hardening corrections.
Cons:
- Streaks and dark bands artifacts can affect the interpretation of CT images, especially when evaluating regions with high density objects.
🔍 Minimizing Beam Hardening Artifacts
To minimize the occurrence of beam hardening artifacts, several techniques are used. Filtration is applied to pre-harden the X-ray beam by using flat pieces of uniform alternating material placed at the entry point of the beam. Additionally, calibration corrections using uniform phantoms can help correct for cupping artifacts. Beam hardening correction software, such as iterative algorithms, can further reduce the impact of beam hardening artifacts.
Partial Volume Artifacts
🔍 Causes and Effects
Partial volume artifacts occur when a dense object protrudes partially into the width of the X-ray beam. This can result in inaccurate representations of the object's density, leading to blurring or inaccurate CT numbers. These artifacts are best avoided by using thin-section acquisitions, which can considerably minimize partial volume artifacts and improve the accuracy of image reconstruction.
Pros:
- Thin-section acquisitions can significantly reduce partial volume artifacts.
- Minimizing partial volume artifacts enhances the image resolution and diagnostic accuracy.
Cons:
- In some cases, obtaining thin-section acquisitions may require longer scan times.
🔍 Minimizing Partial Volume Artifacts
To minimize partial volume artifacts, thin-section acquisitions are recommended. The use of high-resolution techniques such as 3D image reconstruction can further improve the accuracy of image representation. By selecting appropriate scan parameters and ensuring the object is well-centered within the X-ray beam, the impact of partial volume artifacts can be significantly reduced.
Under Sampling Artifacts
🔍 View Aliasing
Under sampling artifacts occur when there is a large interval between projections, resulting in misregistration and blurring of sharp edges and small objects. This phenomenon, known as view aliasing, manifests as fine stripes radiating from the edge of a dense structure in the image.
Pros:
- Under sampling artifacts can be minimized by increasing the number of projections per rotation, reducing the interval between projections.
Cons:
- Under sampling artifacts can lead to misinterpretation or blurring of structures, affecting diagnostic accuracy.
🔍 Ray Aliasing
Ray aliasing occurs when under sampling happens within the projection. This results in stripes appearing close to structures and can distort the image quality. Specialized high spatial-resolution techniques, such as quarter-data shifting or flying focal spot, can be employed to minimize ray aliasing artifacts.
Pros:
- Specialized techniques like quarter-data shifting or flying focal spot can effectively minimize ray aliasing artifacts.
Cons:
- Implementing specialized techniques may require advanced imaging equipment or software.
Conclusion
Physics-based artifacts are a significant challenge in CT imaging, with various types affecting the quality and accuracy of CT images. Beam hardening artifacts, partial volume artifacts, and under sampling artifacts are among the most common physics-based artifacts. Minimizing these artifacts requires a combination of calibration corrections, beam hardening correction software, and optimized scan parameters. By understanding the causes and characteristics of these artifacts, radiologists and technologists can enhance the quality of CT images and improve diagnostic confidence.
Resources: